Top projects

Eco 113m2 Eco 113m2
"Eco-113" stands for the design of a single-storey house with a double-pitch roof, and rational approach. The design includes four ... Read more >>
Funk 130m2 Funk 130m2
The two-storey house is designed in the best traditions of functional architectural design. The design includes a large drawing room ... Read more >>
City 136m2 City 136m2
The "CITY 136" design is suitable for small families: the house includes four bedrooms and an ensemble of arched windows. ... Read more >>
Double 130m2 Double 130m2
  The "DOUBLE 130" design of a house with two apartments is intended for two families. The apartment blocks are connected ... Read more >>

Technical Data

Nordicon Facade Element System

   The Nordicon Façade System is intended for superior speed and quality of construction. In the Nordicon System, most of the facade elements are prefabricated to speed up on-site work. A practically unlimited choice of exterior cladding and doors and windows allow the precise adaptation of façade design concepts to the variable requirements of different buildings.    As your reliable partner, we provide our expert services from the initial planning stage to the installation. Any issues pertaining to exterior cladding elements and joints are resolved by our designers based on element models. In addition to exterior walls, this element system is also suitable for base floors, intermediate floors and roofs.

Structure

Figure 1. Wall  Structures  made of Thermopanels


1. Cladding options

  • steel, or other metals
  • wood
  • glass
  • natural stone, bricks or clay tiles
  • thin ventilated plaster board
  • insulated plaster
  • ceramic tiles


2. Ventilation ducts 20 mm

  • horizontal runs, e.g. SO1


3. Choice of windshield boards

  • Gypsum boards, 9 mm (TS9)
  • porous wood-fibre sheathing boards, e.g. 12-mm or 25-mm thick
  • plywood, e.g. 6.5-mm or 9-mm thick
  • bitulith, e.g. 12-mm
  • cement-bonded particle board, 4 mm or 8 mm


4. Thermal insulation / thermo-stud

  • Thermal insulation:
    • incombustible
    • design thermal conductivity λ Design = 0.035/0.037 W/m²K (windshield board panel joints are sealed and both sides of the insulation are in contact with insulated surfaces)
  •  Thermo stud
    •  Material S 350GD+Z
    •  T, thermo stud general
    •  TU, U-shaped thermo stud
    •  TC, C-shaped thermo stud

5. Steam-and-moisture insulation film

  • LDPE polyethylene 0.2 mm, SFS 4225, E class UV protected
    • water steam permeability value Wp = 0.002*10-9 kg/(m2sPa)
    • water steam diffusion resistance Zp = 500*109 m2sPa/kg

6. Options for interior panels

  • hardened gypsum board, 13 mm (EK13)
  • thin steel sheet 0.6–1.0 mm + hardened gypsum board 13 mm
  • wood-gypsum board, e.g. 10 mm or 12 mm
  • chipboard, e.g. 10 mm, 11 mm or 12 mm
  • plywood, e.g. 9 mm or 12 mm
  • semi-hard wood fibre board, e.g. 9 mm
  • thin steel sheet, 1.5 mm


Types of Elements

Technical characteristics

 Structure as viewed from the outside in:

 (-)

Gypsum sheathing board, 9 mm

Insulating thermal stud c/c 600, 8-perforated rows/thermal insulation

Steam-and-moisture insulation film

Interior panel sheathing, gypsum board, 13 mm

(+)

U-values

Calculation standard: ISO EN 6946

Frame thickness Thermal conductivity of insulation U value of structure at different stud material thicknesses W/m2K

design value λ

design


Sound insulation

Test standard: EN ISO 140-3:1995 Table 2

Refer Annex 1

Rw (dB) Airborne sound insulation value

RA,tr (=RW+Ctr) (dB) Traffic noise sound insulation value


In detached houses, load-bearing wall structures can also meet REI30 and REI60 in accordance with separate instructions.

R = resistance, E = integrity, I = insulation

 